Doprava zdarma se Zásilkovnou nad 1 299 Kč
PPL Parcel Shop 54 Balík do ruky 74 Balíkovna 49 GLS 54 Kurýr GLS 64 Zásilkovna 44 PPL 99

ICRP Publication 93

Jazyk AngličtinaAngličtina
Kniha Brožovaná
Kniha ICRP Publication 93 ICRP
Libristo kód: 04491002
Nakladatelství Elsevier Health Sciences, května 2005
Digital techniques have the potential to improve the practice of radiology but they also risk the ov... Celý popis
? points 328 b Připravujeme Připravujeme
3 275
Očekávané naskladnění Naskladnění 30. 07. 2024

30 dní na vrácení zboží


Mohlo by vás také zajímat


Destiny's Embrace Beverly Jenkins / Brožovaná
common.buy 195
Modernism and Fascism Roger Griffin / Pevná
common.buy 4 463
Fighting Back Robert C. Davis / Brožovaná
common.buy 1 841
Experiencing Jesus T. D. Jakes / Audio DVD
common.buy 216
Cathy Beck's Fly-fishing Handbook Cathy Beck / Brožovaná
common.buy 452

Digital techniques have the potential to improve the practice of radiology but they also risk the overuse of radiation. The main advantages of digital imaging, i.e. wide dynamic range, post processing, multiple viewing options, and electronic transfer and archiving possibilities, are clear but overexposures can occur without an adverse impact on image quality. In conventional radiography, excessive exposure produces a black film. In digital systems, good images are obtained for a large range of doses. It is very easy to obtain (and delete) images with digital fluoroscopy systems, and there may be a tendency to obtain more images than necessary. In digital radiology, higher patient dose usually means improved image quality, so a tendency to use higher patient doses than necessary could occur. Different medical imaging tasks require different levels of image quality, and doses that have no additional benefit for the clinical purpose should be avoided. Image quality can be compromised by inappropriate levels of data compression and/or post processing techniques. All these new challenges should be part of the optimisation process and should be included in clinical and technical protocols. Local diagnostic reference levels should be re-evaluated for digital imaging, and patient dose parameters should be displayed at the operator console. Frequent patient dose audits should occur when digital techniques are introduced. Training in the management of image quality and patient dose in digital radiology is necessary. Digital radiology will involve new regulations and invoke new challenges for practitioners. As digital images are easier to obtain and transmit, the justification criteria should be reinforced. Commissioning of digital systems should involve clinical specialists, medical physicists, and radiographers to ensure that imaging capability and radiation dose management are integrated. Quality control requires new procedures and protocols (visualisation, transmission, and archiving of the images).

Informace o knize

Plný název ICRP Publication 93
Autor ICRP
Jazyk Angličtina
Vazba Kniha - Brožovaná
Datum vydání 2005
Počet stran 76
EAN 9780080444697
ISBN 0080444695
Libristo kód 04491002
Nakladatelství Elsevier Health Sciences
Váha 150
Rozměry 167 x 238 x 4
Darujte tuto knihu ještě dnes
Je to snadné
1 Přidejte knihu do košíku a zvolte doručit jako dárek 2 Obratem vám zašleme poukaz 3 Kniha dorazí na adresu obdarovaného

Přihlášení

Přihlaste se ke svému účtu. Ještě nemáte Libristo účet? Vytvořte si ho nyní!

 
povinné
povinné

Nemáte účet? Získejte výhody Libristo účtu!

Díky Libristo účtu budete mít vše pod kontrolou.

Vytvořit Libristo účet