Fan-Beam Multiplexed Compton Scatter Tomography for Single-Sided Noninvasive Inspection

Jazyk AngličtinaAngličtina
Kniha Brožovaná
Kniha Fan-Beam Multiplexed Compton Scatter Tomography for Single-Sided Noninvasive Inspection Brian L Evans
Libristo kód: 08243307
Nakladatelství Biblioscholar, listopadu 2012
Energies, the scattered gamma ray spectra are significantly influenced by the momentum distribution... Celý popis
? points 150 b
1 502 včetně DPH
Skladem u dodavatele Odesíláme za 15-20 dnů

30 dní na vrácení zboží


Mohlo by vás také zajímat


Energies, the scattered gamma ray spectra are significantly influenced by the momentum distribution of the electrons in the target, a phenomenon known as Doppler broadening. This broadening is energy-variant and the shape is a function of scattering material. A deterministic system model is developed that implements advanced features such as Doppler broadening, extended source and detector sizes, and the spatially-variant and energy-variant aspects of detector response. These features allow direct simulation without convolving an idealized model with an experimentally-measured detector response function. Likewise, it allows the direct use of measured spectra for image reconstruction without deconvolving the detector response function. Two novel approaches to image reconstruction are developed, one based on filtered backprojection and another based on an iterative technique. The filtered backprojection method requires unfolding a scattering angle distribution from each measured energy distribution. Several iterative methods are described to perform this unfolding step. The iterative image reconstruction method is based on a penalized weighted least-squares (PWLS) linear system solution, but implements a two-level iteration to account for nonlinear implicit dependencies in the system. A demonstration MCST system was assembled from components available commercially. This system includes a 6-element array of HPGe detectors, a 109Cd radionuclide that emits 88 keV gammas, and fan beam collimators developed specifically for this system. It is used to produce the first one-sided MCST images from several aluminum phantoms. This validates the system model and iterative image reconstruction algorithm, and demonstrates the feasibility of the one-sided MCST technique. The response of a next-generation MCST system is simulated. The simulations address such issues as the contrast recovered from various samples, system efficiencies, and counting times.

Informace o knize

Plný název Fan-Beam Multiplexed Compton Scatter Tomography for Single-Sided Noninvasive Inspection
Jazyk Angličtina
Vazba Kniha - Brožovaná
Datum vydání 2012
Počet stran 172
EAN 9781288317387
ISBN 9781288317387
Libristo kód 08243307
Nakladatelství Biblioscholar
Váha 318
Rozměry 189 x 246 x 9
Darujte tuto knihu ještě dnes
Je to snadné
1 Přidejte knihu do košíku a zvolte doručit jako dárek 2 Obratem vám zašleme poukaz 3 Kniha dorazí na adresu obdarovaného

Přihlášení

Přihlaste se ke svému účtu. Ještě nemáte Libristo účet? Vytvořte si ho nyní!

 
povinné
povinné

Nemáte účet? Získejte výhody Libristo účtu!

Díky Libristo účtu budete mít vše pod kontrolou.

Vytvořit Libristo účet