Doprava zdarma se Zásilkovnou nad 1 499 Kč
PPL Parcel Shop 54 Balík do ruky 74 Balíkovna 49 GLS 54 Kurýr GLS 74 Zásilkovna 49 PPL 99

Evaluation of a Networked Radiation Detection System

Jazyk AngličtinaAngličtina
Kniha Brožovaná
Kniha Evaluation of a Networked Radiation Detection System Leif A Hansen
Libristo kód: 08130991
Nakladatelství Biblioscholar, září 2012
First responders assess a Nuclear/Radiological (NUCRAD) event in a timely and accurate manner by cre... Celý popis
? points 150 b
1 502 včetně DPH
Skladem u dodavatele Odesíláme za 15-20 dnů

30 dní na vrácení zboží


Mohlo by vás také zajímat


First responders assess a Nuclear/Radiological (NUCRAD) event in a timely and accurate manner by creating a site characterization that reflects the location of various levels of contamination based on their instruments' readings. The survey team experiences difficulty in accurately recording this critical data due to the challenge of operating multiple devices and communicating the devices' readings to other survey members. First responders produce a representation of the contamination or activity on a map that contain rings outlining the levels of activity and/or single locations of a single activity. Recently, several agencies began creating software programs that record a first responder's instrument readings, time, and the global positioning system (GPS) location plotting the information in real-time. The Environmental Protection Agency (EPA) Region 5 developed the Rapid Assessment Tool (RAT). This research evaluates the effectiveness of RAT by comparing the timeliness and accuracy of the site characterization created by multiple survey teams (one team not using RAT and another team using RAT). All of the Bioenvironmental Engineer (BEE) Survey Teams using RAT decreased their survey times for all scenarios. The Weapons of Mass Destruction - Civil Support Team (WMD-CST) survey teams using RAT decreased their survey times during the lane, bounce and bypass, star, and cloverleaf scenarios. However, survey times increased for the zigzag and radial scenarios.

Informace o knize

Plný název Evaluation of a Networked Radiation Detection System
Jazyk Angličtina
Vazba Kniha - Brožovaná
Datum vydání 2012
Počet stran 162
EAN 9781249362555
ISBN 9781249362555
Libristo kód 08130991
Nakladatelství Biblioscholar
Váha 299
Rozměry 189 x 246 x 9
Darujte tuto knihu ještě dnes
Je to snadné
1 Přidejte knihu do košíku a zvolte doručit jako dárek 2 Obratem vám zašleme poukaz 3 Kniha dorazí na adresu obdarovaného

Přihlášení

Přihlaste se ke svému účtu. Ještě nemáte Libristo účet? Vytvořte si ho nyní!

 
povinné
povinné

Nemáte účet? Získejte výhody Libristo účtu!

Díky Libristo účtu budete mít vše pod kontrolou.

Vytvořit Libristo účet