Doprava zdarma se Zásilkovnou nad 1 499 Kč
PPL Parcel Shop 54 Balík do ruky 74 Balíkovna 49 GLS 54 Kurýr GLS 74 Zásilkovna 49 PPL 99

Chromium Concentration Bias in the Particle Size Distribution of Primer Overspray

Jazyk AngličtinaAngličtina
Kniha Brožovaná
Kniha Chromium Concentration Bias in the Particle Size Distribution of Primer Overspray Joseph M Fox
Libristo kód: 08251199
Nakladatelství Biblioscholar, prosince 2012
Air Force aircraft-painting operations create clouds of paint overspray that contain strontium chrom... Celý popis
? points 150 b
1 502 včetně DPH
Skladem u dodavatele Odesíláme za 15-20 dnů

30 dní na vrácení zboží


Mohlo by vás také zajímat


Destination Marketing Organisations Steven Pike / Pevná
common.buy 4 944
Statik Im Stahlbetonbau Kurt Beyer / Brožovaná
common.buy 1 812
Carylls. a Novel. Francis Bart Vincent / Brožovaná
common.buy 680

Air Force aircraft-painting operations create clouds of paint overspray that contain strontium chromate, a confirmed carcinogen, which poses an exposure hazard to painters. It is often assumed that all particles in paint overspray have the same chemical composition as the original paint mixture, however differences in composition may occur in various particle sizes. Because particle size affects where in the respiratory system a particle deposits, actual exposures to a specific chemical may vary. Paint particles greater than 2.5 um are deposited in the upper respiratory system and will be eliminated by physiological removal mechanisms. Particles less than 2.5 um will deposit in the pulmonary region of the lungs where removal processes are slower. Currently it is assumed for the purposes of industrial hygiene evaluations that there is an equal distribution of chromate across all paint particle sizes. Particle size distributions were collected on digestible cellulose substrates during painting operations using two 7-stage cascade impactors. Each substrate was weighed before and after collection to determine total mass collected at each particle size and then samples were digested and analyzed for chromium mass by atomic absorption spectrometry. In particles smaller than 2.5 um, chromium concentrations per total mass collected averaged 21 ug of chromium/mg of total mass collected. Particles larger than 2.5 um averaged 75 ug/mg. A Wilcox in ranked sum test was used to evaluate the two data groups and found a statistically significant difference between the two particle size groups, indicating that less chromium is found in particles most likely to deposit reach the pulmonary region of the lungs.

Informace o knize

Plný název Chromium Concentration Bias in the Particle Size Distribution of Primer Overspray
Autor Joseph M Fox
Jazyk Angličtina
Vazba Kniha - Brožovaná
Datum vydání 2012
Počet stran 88
EAN 9781288416745
ISBN 9781288416745
Libristo kód 08251199
Nakladatelství Biblioscholar
Váha 172
Rozměry 189 x 246 x 5
Darujte tuto knihu ještě dnes
Je to snadné
1 Přidejte knihu do košíku a zvolte doručit jako dárek 2 Obratem vám zašleme poukaz 3 Kniha dorazí na adresu obdarovaného

Přihlášení

Přihlaste se ke svému účtu. Ještě nemáte Libristo účet? Vytvořte si ho nyní!

 
povinné
povinné

Nemáte účet? Získejte výhody Libristo účtu!

Díky Libristo účtu budete mít vše pod kontrolou.

Vytvořit Libristo účet