Doprava zdarma se Zásilkovnou nad 1 499 Kč
PPL Parcel Shop 54 Balík do ruky 74 Balíkovna 49 GLS 54 Kurýr GLS 74 Zásilkovna 49 PPL 99

Characterization of a Polymer-Based MEMS Pyroelectric Infrared Detector

Jazyk AngličtinaAngličtina
Kniha Brožovaná
Kniha Characterization of a Polymer-Based MEMS Pyroelectric Infrared Detector Mark E Allard
Libristo kód: 08141940
Nakladatelství Biblioscholar, října 2012
AFRL/MLPJE had developed a novel thermal sensing material termed proteinimpregnated- polymer (PIP).... Celý popis
? points 150 b
1 502 včetně DPH
Skladem u dodavatele Odesíláme za 15-20 dnů

30 dní na vrácení zboží


Mohlo by vás také zajímat


Panamaris Move to Brazil Sari Kola and Kim Nystrom / Pevná
common.buy 873
Life of Dr Oliver Goldsmith Richard Glover / Brožovaná
common.buy 382
Lost C C Lea / Brožovaná
common.buy 516
Tortured Smile Jeffrey C Armstrong / Brožovaná
common.buy 543
Die makrookonomischen Determinanten des DAX Dirk Rathjen / Brožovaná
common.buy 1 789

AFRL/MLPJE had developed a novel thermal sensing material termed proteinimpregnated- polymer (PIP). Thus far, a proof-of-concept has been demonstrated using a macro-sized pixel (0.64 mm2) as a bolometric detector. In an effort to better characterize this novel thermal sensing material, experimental data was used to determine figures of merit (FOMs) comparative to off-the-shelf thermal detectors. Microelectromechanical (MEMS) pixels were designed and used as the support structure for an inkjet-deposited droplet of the PIP. During the material characterization, two observations were made: PIP is a pyroelectric material, and the polymer (polyvinyl alcohol (PVA)) without the protein was found to be more suited for measurements taken on the micro-scaled pixels. Both PVA and PVA doped with carbon black (PVA_CB) were the materials focused on in this research, with the latter being the material used for FOM characterization. Pyroelectric coefficients for PVA and PVA_CB were found to be 755.11 nC/(cm2 K), and 108.32 nC/(cm2 K), respectively, which are both two orders of magnitude higher than values for current pyroelectric polymers. A responsivity of 1.66 104 V/W, thermal time constant of 3.59 sec, noise equivalent power of 21.3 nW, and a detectivity of 1.93 105 cm Hz/W were the FOMs found in this thesis. Although the calculated FOMs are not stellar in comparison to current thermal detector technology, this material shows much promise. The shortfalls in FOMs could potentially be attributed to a poor pixel design. This thesis plants the scientific seed in cultivating a thermal imaging focal plane array (FPA) using a newly found pyroelectric polymer.

Informace o knize

Plný název Characterization of a Polymer-Based MEMS Pyroelectric Infrared Detector
Jazyk Angličtina
Vazba Kniha - Brožovaná
Datum vydání 2012
Počet stran 178
EAN 9781249586562
ISBN 9781249586562
Libristo kód 08141940
Nakladatelství Biblioscholar
Váha 327
Rozměry 189 x 246 x 10
Darujte tuto knihu ještě dnes
Je to snadné
1 Přidejte knihu do košíku a zvolte doručit jako dárek 2 Obratem vám zašleme poukaz 3 Kniha dorazí na adresu obdarovaného

Přihlášení

Přihlaste se ke svému účtu. Ještě nemáte Libristo účet? Vytvořte si ho nyní!

 
povinné
povinné

Nemáte účet? Získejte výhody Libristo účtu!

Díky Libristo účtu budete mít vše pod kontrolou.

Vytvořit Libristo účet